What rules must be followed when wrapping the instruments for the autoclave?
In this video, you get some practical tips on sterilizing your surgical instruments and using an autoclave. This video is the fourth in a series of four to discuss some best practices in caring for your surgical instrument investment. Show Autoclaving, which is saturated steam under high pressure, is the most common method for sterilizing surgical instruments, but a cold sterilization method may also be used. Prior to sterilization, clean the instruments and lubricate all hinged instruments with a surgical instrument lubricant. *Do not use WD-40, oil or other industrial lubricants.*
Cold Sterilization
Cold sterilization involves soaking instruments in a cold sterilant like Cidex® for at least 10 hours. This process may be detrimental to fine instruments. If disinfection is all that is required (and not sterilization) a 10–90 minute soak in Cidex® may be all that is necessary. When using instruments with tungsten carbide inserts, avoid using solutions with benzyl ammonium chloride
AutoclavingIf you prefer to autoclave, instruments may be autoclaved individually or in sets.
Tips for Autoclaving:
Follow the manufacturer’s directions for adjusting the time, temperature and pressure of the autoclave cycle. As a general rule of thumb, process unwrapped instruments at 121°C for 20 minutes at 15 PSI above atmospheric pressure or at 134°C for 3–4 minutes at 30 PSI above atmospheric pressure.
At the end of the autoclave cycle when the pressure reaches zero, unlock autoclave door and open it a centimeter or so to allow the steam to escape. If the autoclave door is opened fully before the drying cycle, cold room air will rush into the chamber, causing condensation on the instruments. This will result in water stains on instruments and also cause wet packs.
Run the drying cycle as recommended by the autoclave manufacturer until all the instruments are dry. It should take about 30 minutes.
Using sterile tongs, remove all the instruments, trays and packages. Allow them to cool to room temperature before storing. Unwrapped items must be used immediately or may be stored in covered, dry, sterile trays for up to a week. Store wrapped packages in a warm, dry, closed cabinet. Instruments remain sterile as long as the wrap is dry and intact.
With proper care and maintenance, your instruments will last for years to come. Understanding the difference between cleaning, disinfecting and sterilizing can safeguard your research and protect your investment in surgical instruments, equipment and laboratory animals. If you have any questions about the care of your surgical instruments, visit our website, or give us a call.
WPI was founded by a researcher who built electrophysiology equipment. Our passion is the advancement of modern research, and our researchers have been serving scientists for nearly 50 years. We offer a broad product line that includes the full range of surgical instruments. We know that surgical instruments are a crucial part of research. With proper care, maintenance and storage, your instruments should last for many years. After a good cleaning and disinfection, your surgical instruments may be sterilized using a variety of methods. The chart below shows two common methods, autoclaving and cold sterilization. Sterilization destroys all microbial life. Some chemical sterilants can be used as high level disinfectants (HLD) when used for shorter exposure periods.
Disposable paper or plastic pouches are ideal for autoclaving individual instruments. Use a pouch wide enough for instruments with ratchet locks, like needle holders and hemostats. The instrument needs to be sterilized in an open (unlocked) position. For sets, unlock all the instruments and sterilize them in an open position. Place heavy instruments on the bottom of the set when two layers are required. Here are a few tips to keep in mind.
Autoclaving
Cold SterilizationMost cold sterilization solutions require a 10-hour immersion to render instruments sterile, but this prolonged chemical action may be more detrimental to surgical instruments than the 20-minute autoclave cycle. If the instruments only need to be disinfected (clean and free of most microorganisms), cold sterilization is acceptable, since disinfection will take place in only 10 minutes. However, to render the instruments sterile (with absolutely no microorganisms surviving), autoclaving is recommended.
If you have questions about your surgical instruments, give us a call at (866) 606-1974 (toll-free in the USA) or email us at [email protected]. What are 3 rules that must be followed when loading an autoclave?Only designated individuals should be allowed to set and/or change parameters for the autoclaves. Before using the autoclave, check inside for any items left by the previous user that could pose a hazard. Clean the drain strainer before loading the autoclave. Always place items in a secondary container.
When packaging instruments for sterilization instruments should be?Sterilization is based on density. The total instrument set weight, including the weight of the instrument container, should not exceed 25 pounds. Because the sterilant must contact all surfaces, the instrument pan must be large enough to distribute all of the instruments so that they are exposed to the sterilant.
Why are instruments wrapped for autoclaving?The purpose of wrapping or packaging instruments prior to sterilization is to maintain sterility after the autoclave process is complete.
|